Resistance Isolator for Pt 100 Type 9180/.0
Resistance Isolator for Pt 100 Type 9180/.0
  • World-wide unique dual channel solution
    • space saving, only 8.8 mm per channel
  • For 2-, 3- and 4-wire circuits
  • Intrinsically safe input [EEx ia] IIC
  • Galvanic isolation between input, output and power supply
  • 1 and 2 channels
  • Installation possible in Zone 2

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Resistance Isolator  for Pt 1000 Type 9180/.1
Resistance Isolator for Pt 1000 Type 9180/.1
  • World-wide unique dual channel solution
    • space saving, only 8.8 mm per channel
  • For 2-, 3- and 4-wire circuits
  • Intrinsically safe input [EEx ia] IIC
  • Galvanic isolation between input, output and power supply
  • 1 and 2 channels
  • Installation possible in Zone 2

 

Zones

0

1

2

20

21

22

Ex i interfaces

X

X

X

X

X

X

Installation in

 

 

X

X

Temperature Transmitter with Output 0/4  ... 20 mA, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.-11
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.-11
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 and 2 channels
  • Signal duplication possible
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC or DIP-switches
  • Installation possible in Zone 2 and Div. 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-5.-13
Temperature Transmitter with Output 0/4 ... 20 mA, without Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-5.-13
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

10648E00

10648E00

Temperature Transmitter without Output 0/4 ... 20 mA, with Limit Value Contact (Field Circuit Ex i) Type 9182/.0-50-12
Temperature Transmitter without Output 0/4 ... 20 mA, with Limit Value Contact (Field Circuit Ex i) Type 9182/.0-50-12
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 and 2 channels
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X X X X X X

Installation in

X

X

Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact (Field Circuit Ex i) Type 9182/10-51-12
Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact (Field Circuit Ex i) Type 9182/10-51-12
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

Temperature Transmitter with Output 0/4  ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-51-14
Temperature Transmitter with Output 0/4 ... 20 mA and Limit Value Contact, SIL 2 (Field Circuit Ex i) Type 9182/10-51-14
  • One unit for nearly all temperature sensors indivdually configurable
  • Intrinsically safe input [Ex ia] IIC
  • 1 channel
  • Galvanic isolation between input, output, power supply and configuration interface
  • Open-circuit and short-circuit monitoring and messaging (can be switched off)
  • Simple configuration with PC
  • Installation possible in Zone 2 and Div. 2
  • Can be used up to SIL 2 (IEC 61508)

 

Zones

0

1

2

20

21

22

Ex i
interfaces

X

X

X

X

X

X

Installation in

X

X

 

10648E00

10648E00