STAHL LOGO

Home

Print

Luminarias de Emergencia

Luminaria compacta de emergencia C-LUX 6108 / 6508 Luminaria compacta de emergencia C-LUX 6108 / 6508
  • Versiones
    • C-LUX 6108 para Zona 1 y Zona 2, Zona 21 y Zona 22
    • C-LUX 6508 para Zona 2, Zona 22
  • Con reactancia electrónica y unidad de emergencia integrada
  • Modos de operación
    • sólo emergencia
    • emergencia con posibilidad de apagado
  • Con ó sin función automática de prueba
  • Para tubos de 8 W, d 16 mm, bi-patilla tipo G5
  • Para instalación a techo y pared
  • Pueden ser equipadas con pictograma para señalización de salida
  • Cierre centralizado
  • Envolvente en poliéster, difusor de policarbonato
Compact Sheet-Steel Emergency Light Fitting Series 6118 (Zone 1) Series 6518 (Zones 2, 21, 22) Compact Sheet-Steel Emergency Light Fitting Series 6118 (Zone 1) Series 6518 (Zones 2, 21, 22)
  • Versions
    • 6118 for use zone 1
    • 6518 for use in zones 2, 21 and 22
  • Electronic ballast and integral emergency light unit
  • For continuous emergency operation 1,5 h
  • Operation modes
    • Maintained operation
    • Maintained operation with switchable emergency light blocking
    • Non-maintained operation
  • With weekly functional test
  • With automatic emergency light duration test
  • With discharge protection and charging voltage limiting
  • With intelligent charging technology
  • For fluorescent lamps 8 W
  • Central lock
  • Housing in powder-coated sheet-steel or in stainless steel
  • Glass cover can be fitted with emergency exit signs to order
Emergency Light Fittings for Fluorescent Lamps Series EXLUX 6008 (Zone 1) EXLUX 6408 (Zones 2, 21, 22) Emergency Light Fittings for Fluorescent Lamps Series EXLUX 6008 (Zone 1) EXLUX 6408 (Zones 2, 21, 22)
  • As pendant or pole-mounting fittings
  • With electronic ballast with integrated emergency light unit
  • For two-pin fluorescent lamps
  • 2 lamp versions:
    18 W and 36 W
  • Central locking
  • All-pole disconnection via N/C switch when opening light fitting or battery enclosure
  • Enclosure in polyester resin
  • Cover in polycarbonate
  • In maintained operation or non-maintained operation with switchable emergency light blocking
  • Operating test, weekly
  • Emergency light duration test (at intervalls of 6 months)
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608 Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608
  • For use in
    • Zone 2
    • Zone 21 and Zone 22
  • For fluorescent lamps 2 x 18 W and 2 x 36 W
  • With electronic ballast and integrated microprocessor controlled emergency lighting electronics
  • For emergency light operation periods of 1.5 or 3 hrs
  • Operating types
    • continuous circuit
    • continuous circuit with switchable emergency light blocking mechanism
  • Intelligent charging method
  • Battery case which can be opened separately for easy change of batteries by means of plug-type contacts
  • Housing made of glass-fibre reinforced polyester resin, diffuser cover made of shockresistant polycarbonate
  • Housing sealed with quick-action fasteners
Luminaria fluorescente de emergencia Serie ECOLUX 6608 Economy Luminaria fluorescente de emergencia Serie ECOLUX 6608 Economy
  • Pueden utilizarse
    • en Zona 2
    • en Zonas 21 & 22
  • Para tubos de 2 x 18 W y 2 x 36 W
  • Con reactancia electrónica y microprocesador incorporado controlando la emergencia
  • Para emergencia de 1.5 horas
  • Método de carga inteligente
  • Envolvente fabricada en poliéster reforzado con fibra de vidrio, difusor de policarbonato resistente al impacto.
  • Carcasa sellada mediante cierres de acción rápida
Sheet-Steel Emergency Light Fitting Series 6018 (Zone 1) Series 6418 (Zones 2, 21 & 22) Sheet-Steel Emergency Light Fitting Series 6018 (Zone 1) Series 6418 (Zones 2, 21 & 22)
  • Versions
    • Series 6018 for use in Zone 1
    • Series 6418 for use in Zone 2, 21 & 22
  • Electronic ballast with integral emergency light unit
  • Emergency light operating duration 1.5 h or 3 h
  • Operation modes
    • Maintained operation or
    • Maintained operation with switchable emergency light blocking
  • With weekly function test
  • With or without emergency light duration test (adjustable in the light fitting)
  • With discharge protection and charging voltage limiting
  • With intelligent charging technology
  • For fluorescent lamps 18 W and 36 W
  • Central lock
  • Enclosure in powder-coated sheet-steel or stainless steel
  • Battery enclosure is to open separately, easy battery exchange via plug contacts
Language